- Automotive Transducer - Industry Transducer
- Traction Transducer - Energy and Automation
- Wi-LEM  


Industry Transducer

Nominal Current Range IPN (A)

Power Supply Range (V)

Typical Accuracy @ 25”ĘC % of IPN

Bandwidth (kHz)

Mounting

Technology

Series

0.1 - 0.4

+/-15

2%

DC - 18

PCB

Fluxgate

CT xxx -P

0.25 - 200

+/- 12...15

0.41 - 0.85%

DC - 200

PCB

C/L

LA 25-200 -P

2 - 100

+/-5

3 - 8%

DC - 105

PCB

O/L

FHS 40- P/SP600

3 - 50

+/-12...15
SP2 + 12...15

1 - 2%

DC - 50

PCB

O/L

HX & HX/SP2

5 - 50

+ 5

1%

DC - 50

PCB

O/L

HXS

5 - 50

+/-15
SP1 +5

1 - 4%

DC - 50

PCB

O/L

HY & HY/SP1

6 - 25

+ 5

0.7%

DC - 200

PCB

C/L

LTS - LTSR-LTSP

16 - 100

+/- 12...15

0.9%

DC - 300

PCB

C/L

LAX 100-NP

25 - 125

+/- 12...15

0.25 - 0.4%

DC - 200

PCB

C/L

LAH

50 - 100

+ 5

1 - 1.7%

DC - 100

PCB

Eta

LAS

50 - 100

+/- 15

1 -2.2%

DC - 50

PCB

O/L

HTY

50 - 400

+ 5

1%

DC - 50

PCB

O/L

HAIS

50 - 400

+/- 12...15

1%

DC - 50

PCB

O/L

HTB

50 - 400

+/-12...+15

1.75%

DC - 50

PCB

O/L

HTB/SP5

50 - 600

+/- 15

1 -1.75%

DC - 50

Panel

O/L

HAL

50 - 600

+/- 15

1 - 3%

DC - 50

Panel/PCB

O/L

HAS

50 - 600

+5

1%

DC - 50

Panel

O/L

HASS

100 - 800

+/- 15

1 - 2.7%

DC - 50

PCB

O/L

HAC

100 - 1000

+/- 15

1 - 1.75%

DC - 50

Panel

O/L

HTA

1000 - 10000

+/- 12...60
0...+24

0.2 - 0.8%

DC - 150

Panel

C/L

LT

200 - 500

+/-12...18

0.3%

DC - 100

Panel

C/L

LA 205 / 305 -S/ -T

200 - 800

+5
Note: offset
rationetric

1%

DC - 20

PCB

O/L

HTFS

200 -2000
50 - 500

+/- 12..15

2.2 - 3.25%

DC - 4 --10

Panel
Split Core

O/L

HOP-HTR

200 - 2000

+/-12...24

0.2 - 0.4%

DC - 150

PCB/Panel

C/L

LF

300 -400

+/-15

0.7 - 1%

DC - 50

Panel

C/L

LA 306-S

500 - 1500

+/- 15

1 - 1.75%

DC - > 25

Panel

O/L

HAT

500 - 2500

+/- 15

1 -3.25%

DC - > 25

Panel

O/L

HAX

4000 - 20 000

+/- 15

1%

DC - 3

Panel

O/L

HAZ

 

 

 

 

 

 

 

1 - 100

+/- 15

<0.25%

500

Panel

Fluxgate C

CT

150 - 600

+/- 15

<0.005%

100

Panel

Fluxgate IT

IT

300

+/- 15

<0.05%

100

Panel

Fluxgate IT

ITB 300-S

400

+/- 15

<0.0033%

100

Panel

Fluxgate IT

IT 400-S

700

+/- 15

<0.0053%

100

Panel

Fluxgate IT

IT 700-S

 This data is for general information only. Please refer to specific data sheet for each product.

 Voltage measurement in industrial applications
With built-in resistor R1 

Nominal Voltage Range VPN (V)

Power Supply Range (V)

Global Accuracy @ +25”ĘC, % of VPN

Bandwidth (kHz)

Mounting

Technology

Series

50 - 2000

+/- 12...24

0.7

<13

Panel

Isolation
Amplifier

AV 100-Voltage

50 - 2000

+/- 15...24

0.7 - 1.2

<10

Panel

C/L

LV 100-Voltage 1

200- 1200

+/- 12...15

0.8 - 0.9

<10

Panel

C/L

LV 25-Voltage

85 -1400

+/- 15...24

<0.375

<300-800

Panel

Fluxgate C

CV 3-Voltage

200 - 6400

+/- 15...24

0.8 - 2.5

<1

Panel

C/L

LV 200-
AW/2/Voltage

2500 - 4000

+/- 15...24

0.2 - 0.8

<10

Panel

C/L

LV 100-Voltage2

2121 - 4242

+/- 15 % +/- 24

<1.4

<21

Panel

Fluxgate C

CV 4-Voltage

 Without resistor R1 

Nominal Voltage Range IPN (VPN)

Supply Range (V)

Global Accuracy @ +25”ĘC, % of IPN

Bandwidth (kHz)

Mounting

Technology

Series

10 mA
(10 - 500V)

+/- 12...15

0.8 - 1

<10

PCB

C/L

LV 25-P

10 -210mA
(100 - 2500V)

+/- 12...24

0.7

<10

Panel

C/L

LV 100

20 mA
(100 - 2500V)

+/- 15...24

0.6

<6

Panel