KOREAN          CONTACT
Home
News
Products
Order



LEM      |     Power One      |     Behlke      |     Data Mars
- Automotive Transducer - Industry Transducer
- Traction Transducer - Energy and Automation
- Wi-LEM  


Traction Transducer

Nominal Current Range Ipn (Apn)

Power Supply Range (V)

Global Accuracy @ +25”ĘC, % of Ipn

Bandwidth (kHz)

Mounting

Technology

Series

0.25 - 200

+/- 12...15

0.4 - 0.9%

DC - 150

PCB

C/L

LA 25-200 -P

100 - 1000

+/- 15

1 - 1.35%

DC - 50

Panel

O/L

HTA Traction

200- 500

+/- 12...24

0.6 - 0.9%

DC - 100

Panel

C/L

LA 205 / 305 -S/ -T Traction

200 - 500

+/- 24

1%

DC - 100

Split core

C/L

LA 200 / 500-SD

200 - 2000

+/- 12...24

0.2 - 0.4%

DC - 150

Panel

C/L

LF Traction

300 - 400

+/-15

0.7 - 1 %

DC - 50

Panel

C/L

LAC 300-S

350 - 500

+/- 15...+/- 24

0.5 - 0.6%

DC - 100

Panel

C/L

LTC 350 - 500

250 - 4400

+/- 15..60
...+24

0.2 - 0.8%

DC - 150

Panel

C/L

LT Traction

500 -1000

+/- 15... +/- 24

0.4 - 0.7%

DC - 100

Panel

C/L

LTC 600 - 1000

500 - 3000

+/- 15

2.8%

DC - 10

Panel

O/L

HTC

1000

+/- 15

1.2%

DC - 10

Panel

O/L

HAR

4000 - 20000

+/- 15

1%

DC - 3

Panel

O/L

HAZ

 

 

 

 

 

 

 

<20 A AC on
<3000 A DC

+/- 15

<5 %

10 - 3000Hz

Panel

Rogowski

RA Interference Current Measurement

 

 

 

 

 

 

 

+/- 2

+/- 15

2.5 %

5

Panel

Fluxgate C

CD Differential Current Measurement


Data is for general information only, Please refer to specific data sheet for each product.

Current measurement in trackside railway applications

Nominal Current Range Ipn (A)

Power Supply Range (V)

Global Accuracy @ +25”ĘC, % of Ipn

Bandwidth (kHz)

Mounting

Technology

Series

10 - 30

0...+24

1

DC...1

Panel / Rail
DN

C/L

Points Conditions Monitoring (PCM)

 
Voltage measurement in traction on-board applications

With built-in resistor R1

Nominal Voltage Range Vpn

Power Supply Range (V)

Global Accuracy @ +25”ĘC, % of Ipn

Bandwidth (kHz)

Mounting

Technology

Series

50 -2000

+/- 12...24

0.7

<13

Panel

Isolation Amplifier

AV 100-Voltage

50 - 2000

+/- 15...24

0.7 - 1.2

<10

Panel

C/L

LV 100-Voltage 1

85 - 1400

+/- 15...24

<0.375

<300 - 800

Panel

Fluxgate C

CV 3-Voltage

200 - 1200

+/- 12...15

0.8 - 0.9

<10

Panel

C/L

LV 25-Voltage

200 - 6400

+/- 15...24

0.8 - 2.5

<1

Panel

C/L

LV 200-AW/2/Voltage

2121 - 4242

+/- 15 & +/- 24

<1.4

<21

Panel

Fluxgate C

CV 4-Voltage

2500 - 4000

+/- 15...24

0.2 - 0.8

<10

Panel

C/L

LV 100-Voltage 2


Without resistor R1

Nominal Voltage Range Ipn (Vpn)

Power Supply Range (V)

Global Accuracy @ +25”ĘC, % of Ipn

Bandwidth (kHz)

Mounting

Technology

Series

10 mA
(10 - 500V)

+/- 12...15

0.8 - 1

<10

PCB

C/L

LV 25-P

10 - 210 mA
(100 - 2500V)

+/- 12...24

0.7

<10

Panel

C/L

LV 100

20 mA
(100 - 2500V)

+/- 15...24

0.6

<6

Panel

C/L

LV 200-AW/2

  C.P.O. Box 10265 Seoul, Korea